Loading...
Protected by IronClad Assurance
This lot has been given an extensive inspection by an industry expert. If you find it's not as described, file a dispute and we'll make it right.
ID number
#15726442
In yard
No
Features
Air Conditioner, Anti Two-Block, PAT DS350 Load Moment Indicator, 12169 hrs Crane Operation, 2001 US EPA Label, Cummins C8.3-C 6 Cylinder 215 hp 8.3 L Diesel Engine, 36 ft Minimum 110 ft Maximum Boom Length, Auxiliary Hoist, Rooster Sheave, 33 ft to 56 ft Bifold Swingaway Offset Jib, 1000 lb 50 ton Capacity McKissick 4 Sheave Hook Block, 300 lb Overhaul Ball




















Serial Number / VIN
222594
CE Mark
No CE mark found
Hour Meter / Odometer
12169 hrs, Meter inoperable-No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Paint
Sheet Metal (fiberglass) Condition
Steps/Ladders
Hand Rails
Glass
Exterior Lights
Some not operational, Front and lower rear work lights are not operational
Safety Certification Label
There is a safety certification label with a date of 12-18-24
Safety Certification Report
Safety Certification Report Available
Load Chart
Yes


Travel Alarm
Operational
Horn
Operational
Seat Belts
Operational
Safety Lock Out/Stop
Operational
Current Safety Manual
Current Operator/Maintenance Manual
Hours of Crane Operation
12169 hrs Crane Operation





















Mirrors
Glass
No visible damage
Seats/Armrests
Load Moment Indicator
Operational
Anti Two Block
Operational
Hydraulic Controls
Drivetrain Controls
Oil Pressure
The gauge registers in the operating range. 25 PSI
Warning Lights
Operational
Gauges
Operational
Drum Rotation Indicator
Operational
Air Conditioner
Operational
Heater
Operational
Limited Function Check
The main components are in place and operational as noted.

















Emissions Status
Other 2001 US EPA Label
Emission Label
A/C Compressor
Operational
Blow-by (subjective visual observation)
No noticeable vapor or pressure
Starter
Operational
Exhaust System
Radiator
Oil Leaks
No dripping leaks Seepage
Fuel Leaks
No dripping leaks
Cooling System Leaks
No dripping leaks
Engine - Left Side
Engine - Right Side
Limited Function Check
The engine started and ran.








Transmission
Operational
Front Drive Axle
Rear Drive Axle
Final Drives
Limited Function Check
The drivetrain was operational.
























Pumps (Hydraulics)
Hydraulic Motors
Valves
Dripping leak, Small valve leaking underneath
Hydraulic Tank
Hoses (Hydraulic)
Swing Motor
Main Hoist
Auxiliary Hoist
Lift Cylinders
Telescopic Boom Cylinders
Cylinder not accessible
Cylinder Pins and Bushings
Limited Function Check
The hydraulic system was operational.













































Steering Linkage
Steering Cylinders
Steering Wheel Play
Suspension Cylinders
Brake Type
Hydraulic
Master Cylinder/Brake Control
Brake Lines/Hoses
Park Brake
Limited Function Check - Brakes
The brake system functioned, stopping and holding the machine.
Turntable Bearing
Frame Condition
Tire Size
All of the tires are the same size, 29.5-25 Front tires, 29.5-25 Rear tires
Left Front Tire
Left Rear Tire
Right Rear Tire
Right Front Tire
Wheel Condition
Wheel Studs
Limited Function Check
The main chassis components were operational in a limited check.
Outrigger Cylinders
Extension cylinder or hose leaking. Cannot confirm source.
Outrigger Condition
Outrigger Beams
Outrigger Floats/Pads Condition
Main Boom Pins
Main Boom Sections
Sheaves
Boom Head Section
Wear Pads
Limited Function Check
The main crane components functioned when checked without a load.











Jib
Main Load Block
Overhaul Ball
Counterweights
No additional counterweights
Oil Sample Analysis
| engine | transmission | |
|---|---|---|
| date of analysis | Aug 25, 2026 | Aug 25, 2026 |
| Silicon | 8.68 PPM | 10.77 PPM |
| Tin | 0.5 PPM | 0 PPM |
| Silver | 0.02 PPM | 0.3 PPM |
| Aluminum | 1.49 PPM | 2.66 PPM |
| Chromium | 0.46 PPM | 0.17 PPM |
| Lead | 1.06 PPM | 64.13 PPM |
| Copper | 0.33 PPM | 161.02 PPM |
| Nickel | 0.06 PPM | 0.16 PPM |
| Iron | 9.52 PPM | 16.99 PPM |
| Glycol | NEG | N/A |
| Water | NEG | N/A |
| Fuel | <5% | N/A |
Items must be paid in full by Wednesday, January 8, 3000. Late fees will be applied after due date.
Get your equipment to where it needs to be with Ritchie Bros.' full-service door-to-door logistics and shipping solutions. We take care of every step of the journey with our all-inclusive service to get your equipment across borders, continents and oceans quickly and efficiently
The detailed equipment information is limited in scope, and Ritchie Bros. Auctioneers has not inspected any aspects or components of the equipment other than those expressly set forth herein. Unless expressly stated, we make no representations or warranties, express or implied, concerning the equipment or its components, including without limitation any representations or warranties concerning functionality, conformity or compliance with any safety standard or requirement of any applicable authority or regulatory body, fitness for any particular purpose, or merchantability. You are strongly advised to perform your own detailed inspection of the equipment prior to bidding.
Equipment is not tested under load or operated in all available gears. We make no representation or warranty that equipment is operating in accordance with manufacturers' specifications. No inspection has been performed with respect to any functionality aspect other than those expressly included herein. Only select photos have been provided for individual undercarriage components, and may not be indicative of the condition of the entire undercarriage as a whole.
Measurements are given as an estimate only. Actual loaded dimensions may vary based on truck/trailer height and the loaded machine configuration/position. It is the buyer's responsibility to measure all loads before leaving our auction site to ensure the load is safe for transport. All measurements should be verified by the buyer. Do not rely on these measurements for transportation purposes.